- Products
- Cables
- Indoor Cables
- Flame Retardant Slim Indoor Cable – Slim
TOL4059013+A
Flame Retardant Slim Indoor Cable – Slim
GNHQ 12-96 fibers G657A2 Eca StdE
- Up to 96 fibers
- Super slim design
- Excellent installation performance
- Unique design with robust inner tubes that does not kink
- Temperature range from -40 to +70°C
- Easy to prepare and identify fibers
- Indoor, flame retardant
- Bend resistant G657A2 fiber
- Up to 96 fibers
- Super slim design
- Excellent installation performance
- Unique design with robust inner tubes that does not kink
- Temperature range from -40 to +70°C
- Easy to prepare and identify fibers
- Indoor, flame retardant
- Bend resistant G657A2 fiber
The cable is a fiber optic micro cable for indoor installation. Typical applications are for installations in vertical risers for multi dwelling units in FTTH networks.
Micro cable based on a slim loose tube design with up to eight tubes per cable. The design facilitates fiber preparation and mid-span access. The cable contains bend-resistant G657A2 fibers that gives the cable excellent bend performance.
- Primary coated fiber: Silica, acrylate
- Loose tube: PA
- Filling compound: Thixotropic gel
- Central strength member: Glass fiber reinforced plastic
- Slit up yarn: Aramide yarn
- Water blocking elements (dry)
- Outer sheath: Polyethylene, flame retardant, halogen-free
Black fillers can replace empty white tubes.
Technical Information
Product Color | Yellow sheath |
---|---|
Color Code | STDE |
Temperature, Operation [°C] | -40 to +70 |
Temperature, Storage [°C] | -40 to +70 |
Temperature, Installation [°C] | -15 to +50 |
Water Blocking | Longitudinal water blocking in accordance with IEC 60794-1-2-F5B. |
Reaction to Fire | Flame resistance according to IEC 60332-3-24 and CE Eca EN50575:2014 |
Fiber Type | G657A2 |
Attenuation @Wavelength [nm] | 1310/1550/1625 |
Average Attenuation [dB/km] | 0.36/0.22/0.25 |
Maximum Attenuation [dB/km] | 0.38/0.25/0.30 |
Conformance | Longitudinal water blocking according to IEC 60794-1-2-F5B. Mechanical and environmental tests in accordance with IEC 60794-5-10. Fiber parameters and tests according to the IEC series 60793-2 and 60793-1. |
Marking | Example of sheath marking, 1 time/meter: “HEXATRONIC yymmddhh TOL4059013/zzA GNHQBDUV zz G.657.A2 xxxx m" where yymmddhh= year, month, day and hour of manufacture, zzz=number of fibers in cable, xxxx=running meter marking |
Installation Notes | If the cable is installed by blowing the temperature shall be -15 to +40°C. The cable shall not be stored in direct sunlight. The sun may heat up the cable over the permitted temperature limit. |
Ordering Information | Supplied lengths: 2 or 4 km |