The product assortment on this website may differ from what is available where you are located. Do you want to visit the American website instead?

TOL4059013+A

Flame Retardant Slim Indoor Cable – Slim

GNHQ 12-96 fibers G657A2 Eca StdE

  • Up to 96 fibers
  • Super slim design
  • Excellent installation performance
  • Unique design with robust inner tubes that does not kink
  • Temperature range from -40 to +70°C
  • Easy to prepare and identify fibers
  • Indoor, flame retardant
  • Bend resistant G657A2 fiber
  • Up to 96 fibers
  • Super slim design
  • Excellent installation performance
  • Unique design with robust inner tubes that does not kink
  • Temperature range from -40 to +70°C
  • Easy to prepare and identify fibers
  • Indoor, flame retardant
  • Bend resistant G657A2 fiber

The cable is a fiber optic micro cable for indoor installation. Typical applications are for installations in vertical risers for multi dwelling units in FTTH networks.

Micro cable based on a slim loose tube design with up to eight tubes per cable. The design faci­litates fiber preparation and mid-span access. The cable contains bend-resistant G657A2 fibers that gives the cable excellent bend performance.

Flame Retardant Slim Indoor Cable - Slim - Technical Details
  1. Primary coated fiber: Silica, acrylate
  2. Loose tube: PA
  3. Filling compound: Thixotropic gel
  4. Central strength member: Glass fiber reinforced plastic
  5. Slit up yarn: Aramide yarn
  6. Water blocking elements (dry)
  7. Outer sheath: Polyethylene, flame retardant, halogen-free

Black fillers can replace empty white tubes.

Technical Information

Product Color Yellow sheath
Color Code STDE
Temperature, Operation [°C] -40 to +70
Temperature, Storage [°C] -40 to +70
Temperature, Installation [°C] -15 to +50
Water Blocking Longitudinal water blocking in accordance with IEC 60794-1-2-F5B.
Reaction to Fire Flame resistance according to IEC 60332-3-24 and CE Eca EN50575:2014
Fiber Type G657A2
Attenuation @Wavelength [nm] 1310/1550/1625
Average Attenuation [dB/km] 0.36/0.22/0.25
Maximum Attenuation [dB/km] 0.38/0.25/0.30
Conformance Longitudinal water blocking according to IEC 60794-1-2-F5B.
Mechanical and environmental tests in accordance with IEC 60794-5-10.
Fiber parameters and tests according to the IEC series 60793-2 and 60793-1.
Marking Example of sheath marking, 1 time/meter:
“HEXATRONIC yymmddhh TOL4059013/zzA GNHQBDUV zz G.657.A2 xxxx m"
where yymmddhh= year, month, day and hour of manufacture, zzz=number of fibers in cable, xxxx=running meter marking
Installation Notes If the cable is installed by blowing the temperature shall be -15 to +40°C. The cable shall not be stored in direct sunlight. The sun may heat up the cable over the permitted temperature limit.
Ordering Information Supplied lengths: 2 or 4 km