TOL4059011+A

Flame Retardant Indoor Cable – Slim

GNHQ 12-96 fibers G657A1 Eca StdE

  • Up to 96 fibers
  • Excellent bend performance
  • Excellent installation performance
  • Easy to strip and identify fibers
  • Very good temperature performance
  • Length water blocked
  • Halogen-free flame retardant
  • G657A1 bend resistant fiber
  • Up to 96 fibers
  • Excellent bend performance
  • Excellent installation performance
  • Easy to strip and identify fibers
  • Very good temperature performance
  • Length water blocked
  • Halogen-free flame retardant
  • G657A1 bend resistant fiber

GNHQ is a fiber optic micro cable for indoor installation. Typical applications are for installations in vertical risers for multi dwelling units in FTTH networks

The cable consists of up to 12 loose tubes with 12 fibers per tube. G657A1 fibers are used for improved installation performance.

Flame Retardant Indoor Cable - Slim - Technical Details
  1. Primary coated fiber: Silica, acrylate
  2. Loose tube: PA
  3. Central strength member: Glass fiber reinforced plastic, PE
  4. Filling compound: Thixotropic gel
  5. Slit up yarn: Aramide yarn
  6. Wrapping: Water blocking yarns
  7. Sheath: Polyethylene, halogen-free

Technical Information

Product Color Green sheath
Color Code STDE
Temperature, Operation [°C] -40 to +70
Temperature, Storage [°C] -40 to +70
Temperature, Installation [°C] -15 to +50
Water Blocking Longitudinal water blocking according to IEC 60794-1-2-F5B
Reaction to Fire IEC 60332-3-24, CE Eca EN50575:2014
Fiber Type G657A1
Attenuation @Wavelength [nm] 1310/1550/1625
Average Attenuation [dB/km] 0.36/0.22/0.25
Maximum Attenuation [dB/km] 0.38/0.25/0.30
Conformance Flame resistance according to IEC 60332-2-24 and CE Eca EN50575:2014.
Longitudinal water blocking according to IEC 60794-1-2-F5B.
Mechanical and environmental tests in accordance with IEC 60794-5-10.
Fiber parameters and tests according to the IEC series 60793-2 and 60793-1.
Marking Example of sheath marking, 1 time/meter:
“HEXATRONIC A35 yymmddhh TOL4059011/24A GNHQ-I-CDGRV 24/T12 G657A1 STD xxxxx m"
where yymmddhh = year, month, day and hour of manufacture, xxxxx=running meter marking.
Installation Notes The cable should be installed at a temperature between -15 to +40°C. The cable shall not be stored in direct sunlight. The sun may heat up the cable over the permitted temperature limit.
Ordering Information Supplied lengths: 2, 4, 8 km