The product assortment on this website may differ from what is available where you are located. Do you want to visit the American website instead?

TOL4063033+C

FTTx Indoor Drop Cable CCA

1-4 fibers G657B3 TIA598

  • ITU-T G657B3 bend insensitive fiber
  • Tight buffered
  • White discrete coloring
  • Small cable outer diameter
  • High tensile strength
  • LSZH cables compliant to Cca -s1a, d0 -a1
  • Compliant to directive 2002/95/EC (RoHS)
  • ITU-T G657B3 bend insensitive fiber
  • Tight buffered
  • White discrete coloring
  • Small cable outer diameter
  • High tensile strength
  • LSZH cables compliant to Cca -s1a, d0 -a1
  • Compliant to directive 2002/95/EC (RoHS)

The Indoor drop cable is mainly used for FTTx applications but can also be used for cross-connect applications in nodes.

Using bend resistant G657B3 compliant fibers enables the cable to be installed directly on walls, floorboards and similar. In addition, the cable can also be pulled into ducts

and conduits.

The cable has a flame retardant jacket. Aramide yarn is used for increased pull strength. The fibers are tight protected. The cable is CPR rated to Cca.

  1. Optical fiber
  2. Tight buffer
  3. Strength member
  4. Jacket

Technical Information

Product Color White
Color Code TIA598
Temperature, Operation [°C] -20 to +70
Temperature, Storage [°C] -15 to +50
Temperature, Installation [°C] -20 to +70
Water Blocking Length water blocking according to IEC 60794-1-22 Method F5C
Reaction to Fire Cca -s1a, d0 -a1, IEC 60332-1
Fiber Type G657B3
Attenuation @Wavelength [nm] 1310/1550
Maximum Attenuation [dB/km] 0.40/0.30
Insertion Loss, max [dB] 0.25
Conformance

Tensile, short term - IEC 60794-1-21, E1

Tensile, long term - IEC 60794-1-21, E1

Abrasion, cable sheath - IEC 60794-1-21, E2A

Abrasion, cable sheath marking - IEC 60794-1-21, E2B

Crush - IEC 60794-1-21, E3A

Impact - IEC 60794-1-21, E4

Bend, multiple turns - IEC 60794-1-21, E11A

For details on test conditions, contact Hexatronic

Certifications Cca -s1a, d0 -a1
RoHS 2002/95/EC
Marking Example of jacket marking, 1 time/meter:
"HEXATRONIC XXX yymmddtt TOL4063033/1C 1F G657B3 TIA-598 Cca-s1a,d0,a1 xxxxx m"
where XXX = plant code, yymmddhh = year, month, day of manufacture, xxxx=running meter marking