The product assortment on this website may differ from what is available where you are located. Do you want to visit the American website instead?

FDCX-NPA10+

Microduct Connectors, End Stops and Reducers

Fully clear for 3-20 mm microducts

  • Reusable locking clip, to prevent microducts from being accidentally disconnected
  • Fully plastic construction
  • Fully transparent
  • Dark rubber cover
  • UV resistant
  • Easy connection & disconnection
  • Reusable locking clip, to prevent microducts from being accidentally disconnected
  • Fully plastic construction
  • Fully transparent
  • Dark rubber cover
  • UV resistant
  • Easy connection & disconnection

The connectors and end caps for microducts provide a quick, easy and secure connection or water sealing of microducts.

The product comes in three different versions:

  • Straight Connectors are used to join sections of microducts.
  • Reduction Connectors are used to join microducts of different dimensions
  • End Stops are used to block open duct ends and prevent water and dirt from entering the microduct

The connectors are tested for best functionality in combination with the Hexatronic air-blown fibers, nano cables and micro cables.

Working Pressure: 15 Bar

Short-term blowing pressure (10"): 25 Bar

Burst pressure (all diameters): accordingly to EN50411-2-8

Fully plastic construction, safety pre-installed tamper-proof, reusable locking clip system, to prevent microducts from being accidentally disconnected

Fully transparent (clear) body for ease of Visual inspection to ensure the tube is inserted correctly

Union connectors have an internal profile design that allows them not to be affected by the internal diameter of the duct and allows an unobstructed passage for the blown fibres without any obstacles

Dark rubber cover available to prevent the ingress of foreign material and to protect from damage

UV resistant when fitted with a dark rubber cover

Easy connection & disconnection of the duct thanks to the intelligent gripping system

Body: Transparent HP Polymer
Cartridge: Techno Polymer
Collet: Techno Polymer
Seal: NBR
Lock Claw: Stainless Steel
Support Ring: Techno Polymer
Rubber Cover: Dark Silicon
Tamper-Proof Locking Clip: Techno Polymer

Technical Information

Technical Notes

These products have been tested in order to simulate a 20-year lifetime.

EN 50411-2-8: Microduct connectors -specifications
EN 61300-2-4: Microduct Retention
EN 61300-2-10: Crush Resistance
EN 60794-1-2: 2003, Method E4: Impact
EN 61300-2-33: Re-entries
EN 61300-2-22: Change of Temperature (Cycling)
EN 61300-2-23: 1997, Method 2: Water Immersion
EN 61300-2-26: Salt Mist
EN 61300-2-34: Chemical Resistance

EN 50411-2-8, Annex C: High-Pressure Resistance (Safety)

EN 50411-2-8, Annex D: Installation Test

EN 50411-2-8, Annex E: Insertion Force

EN 60529: IP 68
EN 61386-22: Glow wire test at 750°C
EN 61386-24: Conduit systems buried underground