The product assortment on this website may differ from what is available where you are located. Do you want to visit the American website instead?

TOL4043001+A

Underwater Cable – Ribbon

GAHSALTL 12-192 fibers G652D S12

  • For lakes and rivers
  • Water depth down to 100 m
  • Compact design, down to 20 mm in diameter
  • 12 to 192 fibers, G652.D
  • Steel wire reinforcement
  • Water blocking Al-foil
  • For lakes and rivers
  • Water depth down to 100 m
  • Compact design, down to 20 mm in diameter
  • 12 to 192 fibers, G652.D
  • Steel wire reinforcement
  • Water blocking Al-foil

The cable is a single armored, ribbon cable for shallow submarine installations where moderate protection is required.

The cable is suitable for lakes and river crossings in all types of networks such as trunk, metropolitan and fiber access networks.

This submarine cable is based on a slotted core fiber ribbon design for maximum protection. The fibers are protected by an aluminum foil and a polyethylene sheath. Outside the sheath there is a layer of galvanized steel wires covered with a heavy-duty layer of HDPE polymer.

The steel wire reinforcement provides reliable mechanical protection, enabling installation and operation during rough conditions.

Underwater Cable - Ribbon - Technical Details
  1. 4- or 8-fiber ribbon: Silica, acrylate
  2. Filling compoiund: Thixotropic gel
  3. Central strength member: Glass fiber reinforced plastic
  4. Slotted core: Polyethylene
  5. Wrapping: Plastic coated Al-foil
  6. Sheath: Polyethylene
  7. Armouring: Galvanized steel wires
  8. Sheath: Polyethylene

Technical Information

Product Color Black Sheath
Color Code S12
Temperature, Operation [°C] -30 to +60
Temperature, Storage [°C] -40 to +70
Temperature, Installation [°C] -15 to +40
Water Blocking Longitudinal water blocking according to IEC 60794-1-2-F5
Fiber Type G652D
Attenuation @Wavelength [nm] 1310/1550/1625
Maximum Attenuation [dB/km] 0.36/0.23/0.25
Conformance Longitudinal water blocking according to IEC 60794-1-2-F5.
Mechanical and environmental tests in accordance with IEC 60794-1.
Fiber parameters and tests according to the IEC series 60793-2 and 60793-1.
Marking Example of sheath marking, 1 time/meter:
“HEXATRONIC A35 yymmddhh TOL4043001/12A GAHSALTL 12/C4 G.652.D xxxxx m”
where yymmddhh = year, month, day and hour of manufacture, xxxxx=running meter marking.
Installation Notes The cable will sink and in most installations there is no need to add extra weight to keep it in place.
Ordering Information Max continuous length: 10 km (4-96f), 7.8 km (144-192f)