The product assortment on this website may differ from what is available where you are located. Do you want to visit the American website instead?

TOL4059006+A

Flame Retardant Slim Indoor Cable – Slim

GNHQ 12-96 fibers G657A2 UL1685 StdE

  • 12-96 fibers
  • Excellent bend performance
  • Excellent installation performance
  • Easy to strip and identify fibers
  • Length water blocked
  • Halogen-free flame retardant
  • UL1685 Approved
  • 12-96 fibers
  • Excellent bend performance
  • Excellent installation performance
  • Easy to strip and identify fibers
  • Length water blocked
  • Halogen-free flame retardant
  • UL1685 Approved

The cable is a fiber optic micro cable for indoor installation. Typical applications are for installations multi dwelling units in FTTH networks.

Micro cable based on a slim loose tube design with up to eight tubes per cable. The design faci­litates fiber preparation and mid-span access. The cable contains bend-resistant G657A2 fibers that gives the cable excellent bend performance.

Flame Retardant Slim Indoor Cable - Slim - Technical Details
  1. Primary coated fiber: Silica, acrylate
  2. Loose tube: PA
  3. Filling compound: Thixotropic gel
  4. Central strength member: Glass fiber reinforced plastic
  5. Slit up yarn: Aramide yarn
  6. Water blocking yarns)
  7. Outer sheath: Polyethylene, flame retardant, halogen-free

Black fillers can replace empty white tubes.

Technical Information

Product Color Green sheath
Color Code STDE
Temperature, Operation [°C] -10 to +50
Temperature, Storage [°C] -40 to +70
Temperature, Installation [°C] -10 to +50
Water Blocking Longitudinal water blocking according to IEC 60794-1-2-F5B
Reaction to Fire Flame resistance according to IEC 60332-3-24 and UL 1685
Fiber Type G657A2
Attenuation @Wavelength [nm] 1310/1550/1625
Average Attenuation [dB/km] 0.36/0.22/0.25
Maximum Attenuation [dB/km] 0.38/0.25/0.30
Conformance Longitudinal water blocking according to IEC 60794-1-2-F5B.
Mechanical and environmental tests in accordance with IEC 60794-5-10.
Fiber parameters and tests according to the IEC series 60793-2 and 60793-1.
Certifications UL Listed
Marking Example of sheath marking, 1 time/meter:
“HEXATRONIC yymmddhh TOL4059006/24A GNHQBDUV 24 G.657.A2 OFN UL xxxxx m"
where yymmddhh = year, month, day and hour of manufacture, xxxxx=running meter marking.
Installation Notes If the cable is installed by blowing the temperature shall be -10 to +40°C. The cable shall not be stored in direct sunlight. The sun may heat up the cable over the permitted temperature limit.
Ordering Information Supplied length: 4km