TOL4059021+AH

Flame Retardant Indoor/Outdoor Cable

GNHOQ 12-96 fibers G657A1 Dca S12

  • Up to 96 fibers
  • Fiber G657A1
  • Excellent installation performance
  • Easy to strip and identify fibers
  • Very good temperature performance
  • Length water blocked
  • Halogen-free flame retardant - CPR Dca
  • Up to 96 fibers
  • Fiber G657A1
  • Excellent installation performance
  • Easy to strip and identify fibers
  • Very good temperature performance
  • Length water blocked
  • Halogen-free flame retardant - CPR Dca

The cable is a fiber optic micro cable for indoor/outdoor installation. Typical applications are for installations in vertical risers for multi dwelling units in FTTX networks.

The cable consists of up to 8 loose tubes with 12 fibers per tube.

Flame Retardant Indoor/Outdoor Cable - Technical Details
  1. Primary coated fiber: Silica, acrylate
  2. Loose tube: PA
  3. Filling compound: Thixotropic gel
  4. Central strength member: Glass fiber reinforced plastic, coated
  5. Bedding compound, flame retardant
  6. Water blocking element
  7. Slit up yarn
  8. Sheath: Halogen-free, flame retardant polyolefine

Technical Information

Product Color Black sheath
Color Code S12
Temperature, Operation [°C] -45 to +70
Temperature, Storage [°C] -45 to +70
Temperature, Installation [°C] -15 to +40
Water Blocking Water penetration in accordance with IEC 60794-1-22 method F5B.
Reaction to Fire EN 13501-6 CPR classification DCa-s2, d1
Fiber Type G657A1
Attenuation @Wavelength [nm] 1310/1550/1625
Average Attenuation [dB/km] 0.36/0.22/0.25
Maximum Attenuation [dB/km] 0.38/0.25/0.30
Conformance Fire rating according to EN 13501-6 CPR classification DCa-s2, d1.
Longitudinal water blocking according to IEC 60794-1-2-F5B.
Mechanical and environmental tests in accordance with IEC 60794-5-10.
Fiber parameters and tests according to the IEC series 60793-2 and 60793-1.
Certifications Fire rating according to EN 13501-6 CPR classification DCa-s2, d1
Marking

Example of sheath marking. Standard marking 1 time/meter:

“HEXATRONIC yymmddhh TOL4059021/zzA GNHOQ-K-CDGNRV zz/T12 G657A1 Dca-s2,d1 xxxx m"

where yymmddhh= year, month, day and hour of manufacture, zz=number of fibers in cable, xxxx=running meter marking

Installation Notes The cable should be installed at a temperature between -15 to +40°C. The cable shall not be stored in direct sunlight. The sun may heat up the cable over the permitted temperature limit.