The product assortment on this website may differ from what is available where you are located. Do you want to visit the American website instead?

TOL4063031+C

Indoor/Outdoor Dual Purpose Subscriber Drop Cable

1-4f Dual Jacket, G657A2, CPR Cca

  • G657A2 Bend insensitive fibre
  • Tight buffered
  • UV stable outer jacket
  • Small cable outer diameter
  • Aramid yarn high tensile strength
  • Inner LSZH cables compliant to Cca -s1a, d0 -a1
  • Compliant to directive 2002/95/EC (RoHS)
  • G657A2 Bend insensitive fibre
  • Tight buffered
  • UV stable outer jacket
  • Small cable outer diameter
  • Aramid yarn high tensile strength
  • Inner LSZH cables compliant to Cca -s1a, d0 -a1
  • Compliant to directive 2002/95/EC (RoHS)

Drop cable for indoor/outdoor FTTx applications.

The drop cable is primarily intended for direct installation, i.e. installation with clips or routing inside cable raceways and mouldings. This installation technique puts extra tough requirements on the cables in terms of bend performance, crush resistance and other mechanical parameters.

The drop cable has extremely good bend performance due to the G657A2 fiber and the built in bend restriction of the cable design.

The Hexatronic FTTx Internal / External FTTx Drop cable meets of indoor fibre optic distribution requirements and is CPR rated to Cca when the outer UV stable jacket is removed. Crush resistant and suitable for installation with a bend radius down to 7.5mm.

  1. Optical fiber
  2. Tight buffer
  3. Inner strength member
  4. Inner jacket
  5. Outer strength member
  6. Outer jacket

Technical Information

Product Color Black/White
Color Code TIA598
Temperature, Operation [°C] -20 to +70
Temperature, Storage [°C] -15 to +70
Temperature, Installation [°C] -20 to +70
Water Blocking Length water blocking according to IEC 60794-1-2-F5C (Outer jacket only)
Fiber Type G657A2
Attenuation @Wavelength [nm] 1310/1550
Maximum Attenuation [dB/km] 0.40/0.30
Conformance

Tensile, short term - IEC 60794-1-21, E1

Tensile, long term - IEC 60794-1-21, E1

Abrasion, cable sheath - IEC 60794-1-21, E2A

Abrasion, cable sheath marking - IEC 60794-1-21, E2B

Crush - IEC 60794-1-21, E3A

Impact - IEC 60794-1-21, E4

Bend, multiple turns - IEC 60794-1-21, E11A

For details on test conditions, contact Hexatronic.

Certifications Cca -s1a, d0 -a1 (Inner cable)
RoHS 2002/95/EC
Marking Example of jacket marking, 1 time/meter:
"HEXATRONIC XXX yymmddtt TOL4063031/1C 1F G657A2 TIA-598 Cca-s1a,d0,a1 xxxxx m"
where XXX = plant code, yymmddhh = year, month, day of manufacture, xxxx=running meter marking
Installation Notes To enable flame resistance for indoor installations, the black outer jacket shall be removed. The jacket shall not be removed for sections installed outdoors.