ADSS Loose Tube Aerial Cable
GRHLGL 192 fibers G657A1 S12 16 kN
- Concentric core design
- 192 fibers
- Max span length 200-500 m
- Self-supporting
- Non-metallic
The cable is an ADSS, non-metallic cable using concentric core design. The cable is based on the GRHLDV cable but with a layer of aramid yarn as strength member covered with a second sheath enabling a robust cable design.
The cable is suitable for installation in rough climates with high ice-loads and max span length 200-500 m. There is a suitable cable (TOL 403 2002) for shorter length.
It can be installed adjacent to power lines up to 120 kV.
This cable is part of our Aerial Cable System comprising cables, installation and network materials.
The cable is a dual sheathed non-metallic cable using concentric core design and aramide yarns as strength member between the sheaths.
GENERAL ADSS DESIGN
- Primary coated fiber: Silica, acrylate
- Filling compound: Thixotropic gel
- Loose tube: PBT (Color code in picture just as illustration)
- Central strength member: Glass fiber reinforced plastic
- Water blocking: Swellable tape/yarns
- Sheath: Polyethylene (black)
- Strength member: Aramid yarns
- Sheath: Polyethylene (black)
Technical Information
Product Color | Black Sheath |
---|---|
Color Code | STDE |
Temperature, Operation [°C] | -40 to +70 |
Temperature, Storage [°C] | -40 to +70 |
Temperature, Installation [°C] | -15 to +50 |
Water Blocking | Longitudinal water blocking according to IEC 60794-1-2-F5B |
Fiber Type | G657A1 |
Attenuation @Wavelength [nm] | 1310/1550/1625 |
Maximum Attenuation [dB/km] | 0.36/0.23/0.25 |
Conformance | Longitudinal water blocking according to IEC 60794-1-2-F5B. Mechanical and environmental tests in accordance with IEC 60794-1. Fiber parameters and tests according to the IEC series 60793-2 and 60793-1. |
Marking | Example of sheath marking, 1 time/meter: “HEXATRONIC A35 yymmddhh TOL4032035/192AH GRHLGL-L-CDFNRV 192/T24 G657A1 S12 xxxxx m" where yymmddhh = year, month, day and hour of manufacture, xxxxx=running meter marking. |
Installation Notes | The cable can be installed adjacent to power lines up to 120 kV. |
Ordering Information | Supplied lengths: 2, 4, 6 or 8 km |