The product assortment on this website may differ from what is available where you are located. Do you want to visit the American website instead?

MPB4082S+

Cable ducts conforming to DIN 16873

with incorporated push-fit socket

  • direct burial pressureless HEXATRONIC cable ducts made of plasticizer-free polyvinyl chloride
  • quality according to DIN 16873
  • molded cable protection long sleeve according to DIN 16873
  • elastomer sealing ring according to DIN EN 681-1
  • direct burial pressureless HEXATRONIC cable ducts made of plasticizer-free polyvinyl chloride
  • quality according to DIN 16873
  • molded cable protection long sleeve according to DIN 16873
  • elastomer sealing ring according to DIN EN 681-1

Cable ducts and protective ducts are suitable for underground installation as non-pressurized conduits in conjunction with the fittings for protecting power and telecommunications cables against mechanical damage or as cable conduits and for accommodating HexaDuct conduit systems (multiple occupancy conduit).

  • Moulded socket with center sealing ring
  • Spigot end with 15° chamfer and insertion depth marking
  • length 6,0m
  • Ovality < 3.5mm

Technical Information

Product Color RAL 9005
Conformance

Ring stiffness according to EN ISO 9969:

  • Duct series 3: SN 8 (8 kN/m²)
  • Duct series 4: SN 32 (32 kN/m²)

Creep rupture internal pressure test:

  • 17 N/mm² / 60 °C / 1h, DIN 16873
  • 10 N/mm² / 60 °C / 1000h, DIN 16873

Impact test:

  • Breakage rate TIR ≤ 10 % according to DIN 16873, test temperature 0 °C, DIN EN 744.

Thermal shrinkage: ≤ 5% in the longitudinal direction according to DIN EN 743.

Vicat softening temp.: ≥79 °C, DIN EN 727.

Chem. resistance: according to supplement 1 to DIN 8061.

UV stability: 2 years

Density: > 1.4 g/cm³

Flammability: Flame retardant (building material class B1), DIN 4102

Modulus of elasticity according to DIN 53457:

  • Short-term: 3600 N/mm²
  • Long-term: 1750 N/mm²

Surface resistance: > 10^12 Ω

Marking

Standard signatur: HEXATRONIC cable duct, PVC-U, DIN 16873, dimension, month/year

Customer marking on request

Installation Notes According to the installation instructions for PVC-KSR
Ordering Information 6.0 m bars in wooden frame crates