- Products
- Cables
- Loose Tube Cables
- High Performance Loose Tube Cable
TOL4012128+CF
High Performance Loose Tube Cable
GRHL 12-192 fibers G657A1 TIA598A ft
- Up to 192 fibres
- Slim yet very durable design
- Air-blown installation, water jetting or traditional pulling
- The cable can be used as an aerial lashed solution
- Excellent optical performance with ultra-low loss G657A1 fibers
- Dry Core Cable
- Up to 192 fibres
- Slim yet very durable design
- Air-blown installation, water jetting or traditional pulling
- The cable can be used as an aerial lashed solution
- Excellent optical performance with ultra-low loss G657A1 fibers
- Dry Core Cable
The Hexatronic slim outdoor loose-tube cable series combines state of the art installation performance, ultra-low attenuation and a high mechanical and environmental performance.
The cable type is typically used in transport applications such as terrestrial long-haul or metro networks where low attenuation and cable performance are prime concerns.
With a reduced outside cable diameter and optimised cable stiffness, the cables can be air-blown or water-jetted long distances without the need for splicing.
The cables can also be lashed to a messenger wire for aerial installation.
A reduced cable diameter also allows for reduced duct diameters which will simplify and reduce the cost of material handling in field.
Thanks to the central strength member design and a robust sheath the cables can also be installed by traditional pulling techniques.
The cables are based on a dry concentric core, slim loose tube design with up to 16 jelly filled tubes per cable. The cables have one or two layers of inner protective tubes made of a robust PBT compound where each tube has 12 fibers.
The design facilitates easy fibre preparation and mid-span access.
- Primary coated fiber: Silica, acrylate
- Loose tube: PBT, jelly filled
- Central strength member: Glass fiber reinforced plastic, PE
- Slit up yarn: Aramide yarn
- Wrapping: Water blocking yarns
- Sheath: Polyethylene, halogen-free
Black fillers can replace empty white tubes.
Technical Information
Product Color | Black Jacket |
---|---|
Color Code | TIA598 |
Temperature, Operation [°F] | -40 to 158 F (-40 to +70 C, upto 96F) -22 to 158 F (-30 to +70 C, 192F) |
Temperature, Storage [°F] | -40 to 158 F (-40 to +70 C) |
Temperature, Installation [°F] | 5 to 122 F (-15 to +50 C) |
Water Blocking | Length water blocking according to IEC 60794-1-2-F5B |
Fiber Type | G657A1 |
Attenuation @Wavelength [nm] | 1310/1383/1550 |
Typical Attenuation [dB/km] | 0.32/0.32/0.18 |
Average Attenuation [dB/km] | 0.33/0.33/0.21 |
Maximum Attenuation [dB/km] | 0.36/0.36/0.23 |
Conformance | Length water blocking according to IEC 60794-1-2-F5B. Mechanical and environmental test in accordance with IEC 60794-5-10 Fiber parameters and tests according to the IEC series 60793-2 and 60793-1 |
Marking | Example of sheath marking, 1 time/meter: “HEXATRONIC A35 yymmddhh TOL4012128/192CF GRHL-U-CDGNRV 192/T12 G657A1 TIA598 xxxxx ft” where yymmddhh = year, month, day and hour of manufacture, xxxxx=running feet marking |
Installation Notes | If the cable is installed by blowing the temperature shall be -15 to +40°C (5 to 104°F). The cable shall not be stored in direct sunlight. The sun may heat up the cable over the permitted temperature limit. |
Ordering Information | Supplied lengths: 2, 4, 8 km |