The product assortment on this website may differ from what is available where you are located. Do you want to visit the American website instead?

TOL4059022+AH

Flame Retardant Indoor/Outdoor Cable – Slim

GNHOQ 2-24 fibers G657A1 Dca S12

  • Up to 24 fibers
  • Fiber G657A1
  • Excellent installation performance
  • Easy to strip and identify fibers
  • Very good temperature performance
  • Length water blocked
  • Halogen-free flame retardant - CPR Dca
  • Up to 24 fibers
  • Fiber G657A1
  • Excellent installation performance
  • Easy to strip and identify fibers
  • Very good temperature performance
  • Length water blocked
  • Halogen-free flame retardant - CPR Dca

The cable is a fiber optic micro cable for indoor/outdoor installation. Typical applications are for installations in vertical risers for multi dwelling units in FTTX networks.

The cable consists of up to 6 loose tubes with 4 fibers per tube.

Flame Retardant Indoor/Outdoor Cable - Slim - Technical Details
  1. G657A1 fiber
  2. Coating: Acrylate
  3. Loose tube: PA12
  4. Central strength member: Glass fiber reinforced plastic, coated
  5. Water blocking element
  6. Sheath: Halogen-free, flame retardant polyolefine
  7. Bedding compound, flame retardant

Slit up yarn

Technical Information

Product Color Black sheath
Color Code S12
Temperature, Operation [°C] -40 to +70
Temperature, Storage [°C] -40 to +70
Temperature, Installation [°C] -15 to +40
Water Blocking Water penetration in accordance with IEC 60794-1-22 method F5C.
Reaction to Fire EN 13501-6 CPR classification Dca-s2,d2,a3
Fiber Type G657A1
Attenuation @Wavelength [nm] 1310/1550/1625
Average Attenuation [dB/km] 0.36/0.22/0.25
Maximum Attenuation [dB/km] 0.38/0.25/0.30
Conformance

Fire rating according to EN 13501-6 CPR classification DCa-s2, d1.

Fiber parameters and tests according to the IEC series 60793-2 and 60793-1. Mechanical and environmental tests in accordance with Family Specification IEC 60794-5-10.

Test standards, conditions and requirements:

  • Operational temperature: IEC 60794-1-22 Method F1; max attenuation 0.05dB/km*
  • Storage temperature: IEC 60794-1-22 Method F1; max attenuation 0.15dB/km* reversible
  • Ageing: IEC 60794-1-22, Method F9; 168h@85°C,+2 cycles, no attenuation after test
  • Water blocking: IEC 60794-1-2, Method F5C, 3m sample, 1m head of water, no leakage after 24 hours
  • Bend radius: IEC 60794-1-21, Method E11B; 4 turns, 3 cycles, max attenuation 0.05dB*
  • Installation tensile load: IEC 60794-1-21, Method E1; max fiber tension 0.6%, reversible attenuation
  • Crush: IEC 60794-1-21, Method E3; 1 minute load, 100mm plate, no attenuation after test
  • Impact: IEC 60794-1-21, Method E4; 3 different places, max attenuation 0.1dB* after test

* All attenuation measurements performed @ 1550nm

Certifications Fire rating according to EN 13501-6 CPR classification Dca-s2,d2,a3
Marking

Example of sheath marking. Standard marking 1 time/meter:

“HEXATRONIC yymmddhh TOL4059022/zzAH GNHOQ-K-CDGNRV zz/T4 G657A1 Dca-s2,d2,a3 xxxx m"

where yymmddhh= year, month, day and hour of manufacture, zz=number of fibers in cable, xxxx=running meter marking

Installation Notes

Typical installation performance:

  • Ducts ID 8-10 mm: 400 m

Installation performance verified on Hexatronic test track, according to IEC 60794. Installation performance is affected by the installed path, environmental conditions, installation equipment etc and actual performance may therefore deviate from the above specified values.

If the cable is installed by blowing the temperature shall be -15 to +40°C. The cable shall not be stored in direct sunlight. The sun may heat up the cable over the permitted temperature limit.

Minimum bend radius single bend: 40mm

Minimum bend radius 1/4bend (90°): 30mm

Ordering Information 2000m/K6 plastic
4000m/K8 plastic
6000m/K10 plastic
8000m/K10 plastic