- Products
- Cables
- Indoor Cables
- Flame Retardant Indoor/Outdoor Cable – Slim
TOL4059022+AH
Flame Retardant Indoor/Outdoor Cable – Slim
GNHOQ 2-24 fibers G657A1 Dca S12
- Up to 24 fibers
- Fiber G657A1
- Excellent installation performance
- Easy to strip and identify fibers
- Very good temperature performance
- Length water blocked
- Halogen-free flame retardant - CPR Dca
- Up to 24 fibers
- Fiber G657A1
- Excellent installation performance
- Easy to strip and identify fibers
- Very good temperature performance
- Length water blocked
- Halogen-free flame retardant - CPR Dca
The cable is a fiber optic micro cable for indoor/outdoor installation. Typical applications are for installations in vertical risers for multi dwelling units in FTTX networks.
The cable consists of up to 6 loose tubes with 4 fibers per tube.
- G657A1 fiber
- Coating: Acrylate
- Loose tube: PA12
- Central strength member: Glass fiber reinforced plastic, coated
- Water blocking element
- Sheath: Halogen-free, flame retardant polyolefine
- Bedding compound, flame retardant
Slit up yarn
Technical Information
Product Color | Black sheath |
---|---|
Color Code | S12 |
Temperature, Operation [°C] | -40 to +70 |
Temperature, Storage [°C] | -40 to +70 |
Temperature, Installation [°C] | -15 to +40 |
Water Blocking | Water penetration in accordance with IEC 60794-1-22 method F5C. |
Reaction to Fire | EN 13501-6 CPR classification Dca-s2,d2,a3 |
Fiber Type | G657A1 |
Attenuation @Wavelength [nm] | 1310/1550/1625 |
Average Attenuation [dB/km] | 0.36/0.22/0.25 |
Maximum Attenuation [dB/km] | 0.38/0.25/0.30 |
Conformance | Fire rating according to EN 13501-6 CPR classification DCa-s2, d1. Fiber parameters and tests according to the IEC series 60793-2 and 60793-1. Mechanical and environmental tests in accordance with Family Specification IEC 60794-5-10. Test standards, conditions and requirements:
* All attenuation measurements performed @ 1550nm |
Certifications | Fire rating according to EN 13501-6 CPR classification Dca-s2,d2,a3 |
Marking | Example of sheath marking. Standard marking 1 time/meter: “HEXATRONIC yymmddhh TOL4059022/zzAH GNHOQ-K-CDGNRV zz/T4 G657A1 Dca-s2,d2,a3 xxxx m" where yymmddhh= year, month, day and hour of manufacture, zz=number of fibers in cable, xxxx=running meter marking |
Installation Notes | Typical installation performance:
Installation performance verified on Hexatronic test track, according to IEC 60794. Installation performance is affected by the installed path, environmental conditions, installation equipment etc and actual performance may therefore deviate from the above specified values. If the cable is installed by blowing the temperature shall be -15 to +40°C. The cable shall not be stored in direct sunlight. The sun may heat up the cable over the permitted temperature limit. Minimum bend radius single bend: 40mm Minimum bend radius 1/4bend (90°): 30mm |
Ordering Information | 2000m/K6 plastic 4000m/K8 plastic 6000m/K10 plastic 8000m/K10 plastic |