TOL4063027+C

FTTx Indoor Drop Cable Cca

1 fiber G657B3 TIA598

  • ITU-T G.657B3 Bend Insensitive Fibre
  • Tight Buffered
  • Small cable outer diameter
  • Aramid yarn High tensile strength
  • Compliant to Cca
  • Compliant to directive 2002/95/EC (RoHS)
  • ITU-T G.657B3 Bend Insensitive Fibre
  • Tight Buffered
  • Small cable outer diameter
  • Aramid yarn High tensile strength
  • Compliant to Cca
  • Compliant to directive 2002/95/EC (RoHS)

The Indoor drop cable is mainly used for FTTx applications but can also be used for cross-connect applications in nodes.

Using bend resistant G657B3 compliant fibers enables the cable to be installed directly on walls, floorboards and similar. In addition, the cable can also be pulled into ducts

and conduits.

The cable has a flame retardant jacket. Aramide yarn is used for increased pull strength. The fibers are tight protected. The cable is CPR rated to Cca.

FTTx Indoor Drop Cable Cca - Technical Details
  1. Optical fiber
  2. Tight buffer
  3. Strength member
  4. Jacket

Technical Information

Product Color White
Temperature, Operation [°C] -20 to +70
Temperature, Storage [°C] -15 to +50
Temperature, Installation [°C] -20 to +70
Reaction to Fire Cca -s1a, d0 -a1, IEC 60332-1
Fiber Type G657B3
Attenuation @Wavelength [nm] 1310/1550
Maximum Attenuation [dB/km] 0.4/0.3
Conformance

Tensile, short term - IEC 60794-1-21, E1

Tensile, long term - IEC 60794-1-21, E1

Abrasion, cable sheath - IEC 60794-1-21, E2A

Abrasion, cable sheath marking - IEC 60794-1-21, E2B

Crush - IEC 60794-1-21, E3A

Impact - IEC 60794-1-21, E4

Bend, multiple turns - IEC 60794-1-21, E11A

For details on test conditions, contact Hexatronic.

Certifications B2ca
RoHS 2002/95/EC
Marking Example of sheath marking, 1 time/meter:
"HEXATRONIC XXX yymmddtt TOL4063028/1C 1F G657B3 TIA-598 Cca -s1a, d0 -a1 xxxxx m"