We are happy to discuss specifications, use cases, or project needs.
Viper Core Micro Cable - Transport grade - High Capacity
- Up to 864 fibers
- Super slim design
- Optimized cable stiffness for extra long installation by blowing
- Unique design with robust inner tubes that do not kink
- Temperature range from -40 to +70°C
- Excellent bend performance, ≥75 mm
- Easy to prepare and identify fibers
- Ultra low attenuation in cable, Transport grade
The Hexatronic Viper series of micro cables is characterized by state-of-the-art installation performance when installed by blowing into microducts. This series of micro cables is optimized for installation in long-distance networks and transport networks, where the longest possible installation distance and lowest optical attenuation are required.
All parameters, such as cable diameter, jacket friction, cable stiffness, and fiber attenuation, are optimized for the best installation performance without compromising mechanical or environmental properties.
The micro cables are based on a slim loose tube design with up to 36 tubes per cable. The design facilitates fiber preparation and mid-span access. The cables are suitable for long-distance, air-blown installation in microducts, with an inner diameter of as little as 8 to 12 mm. The cables have excellent bend performance and an extremely wide operational temperature range.
The Micro Cables are designed with one or two layers of inner protective tubes made of a unique Polyamide compound.
The Polyamide gives a special strength to the product, while increasing the bending properties as well as other benefits such as extreme temperature resistance. Each tube contains 12 or 24 fibers.
As a result, The Viper Micro Cables are more durable during the installation process as they are able to withstand rough handling. The unique cable design with an extended operational temperature range of -40 to +70°C can be used in many environments, on all continents where heat and cold are often a major concern.

For illustration only. Color code may vary.
1. Primary coated fiber: Silica, acrylate
2. Loose tube: PA
3. Central strength member: Glass fiber reinforced plastic, PE
4. Slit up yarn: Aramide yarn
5. Wrapping: Water blocking yarns
6. Sheath: Polyethylene, halogen-free
Black fillers can replace empty white tubes.
Fiber parameters and tests according to the IEC series 60793-2 and 60793-1. Mechanical and environmental tests in accordance with Family Specification IEC 60794-5-10.
Test standards, conditions and requirements:
- Operational temperature: IEC 60794-1-22 Method F1; max attenuation 0.10dB/km*
- Storage temperature: IEC 60794-1-22 Method F1; max attenuation 0.15dB/km* reversible
- Ageing: IEC 60794-1-22, Method F9; 168h@85°C,+2 cycles, no attenuation after test
- Water blocking: IEC 60794-1-2, Method F5C, 3m sample, 1m head of water, no leakage after 24 hours
- Bend radius: IEC 60794-1-21, Method E11B; 4 turns, 3 cycles, max attenuation 0.05dB*
- Installation tensile load: IEC 60794-1-21, Method E1; max fiber tension 0.6%, reversible attenuation
- Crush: IEC 60794-1-21, Method E3; 1 minute load, 100mm plate, no attenuation after test
- Impact: IEC 60794-1-21, Method E4; 3 different places, max attenuation 0.1dB* after test
* All attenuation measurements performed @ 1550nm
Example of jacket marking, 1 time/foot:
“HEXATRONIC A35 Viper yymmddhh TOL4019049/192C GNHL-U-CDGNRV 192/T12 G657A1 TIA598 xxxxx ft”
where yymmddhh = year, month, day and hour of manufacture, xxxxx=running meter marking
Typical installation performance:
- 40-75% fill ratio, installation according to IEC 60794: 2000 m
- 40-75% fill ratio, straight path: 3000 m
Installation performance is affected by the installed path, environmental conditions, installation equipment etc and actual performance may therefore deviate from the above specified values.
If the cable is installed by blowing the temperature shall be -15 to +40°C. The cable shall not be stored in direct sunlight. The sun may heat up the cable over the permitted temperature limit.
Supplied lengths: 2, 4, 8 km
Technical Information