- Products
- Cables
- Indoor Cables
- Flame Retardant Indoor Cable – Slim
TOL4059011+C
Flame Retardant Indoor Cable – Slim
12-96 fibers G657A1 Eca TIA598
- Up to 96 fibers
- Excellent bend performance
- Excellent installation performance
- Easy to strip and identify fibers
- Very good temperature performance
- Length water blocked - Halogen-free flame retardant
- G657A1 bend resistant fiber
- Up to 96 fibers
- Excellent bend performance
- Excellent installation performance
- Easy to strip and identify fibers
- Very good temperature performance
- Length water blocked - Halogen-free flame retardant
- G657A1 bend resistant fiber
The cable is a fiber optic micro cable for indoor installation. Typical applications are for installations in vertical risers for multi dwelling units in FTTH networks.
The cable consists of up to 12 loose tubes with 12 fibers per tube. G657A1 fibers are used for improved installation performance.
- Primary coated fiber: Silica, acrylate
- Loose tube: PA
- Central strength member: Glass fiber reinforced plastic, PE
- Filling compound: Thixotropic gel
- Slit up yarn: Aramide yarn
- Wrapping: Water blocking yarns
- Sheath: Polyethylene, halogen-free
Technical Information
Product Color | Green sheath |
---|---|
Color Code | TIA598 |
Temperature, Operation [°C] | -40 to +70 |
Temperature, Storage [°C] | -40 to +70 |
Temperature, Installation [°C] | -15 to +50 |
Water Blocking | Longitudinal water blocking according to IEC 60794-1-2-F5B |
Reaction to Fire | Flame resistance according to IEC 60332-3-24 and CE Eca EN50575:2014 |
Fiber Type | G657A1 |
Attenuation @Wavelength [nm] | 1310/1550/1625 |
Average Attenuation [dB/km] | 0.36/0.22/0.25 |
Maximum Attenuation [dB/km] | 0.38/0.25/0.30 |
Conformance | Flame resistance according to IEC 60332-2-24 and CE Eca EN50575:2014. Longitudinal water blocking according to IEC 60794-1-2-F5B. Mechanical and environmental tests in accordance with IEC 60794-5-10. Fiber parameters and tests according to the IEC series 60793-2 and 60793-1. |
Marking | Example of sheath marking, 1 time/meter: “HEXATRONIC A35 yymmddhh TOL4059011/12C GNHQ-I-CDGRV 12/T12 G657A1 TIA-598 xxxxx m” where yymmddhh = year, month, day and hour of manufacture, xxxxx=running meter marking. |
Installation Notes | The cable should be installed at a temperature between -15 to +40°C. The cable shall not be stored in direct sunlight. The sun may heat up the cable over the permitted temperature limit. |
Ordering Information | Supplied lengths: 2, 4, 8 km |